2026-10-13
An electrical design engineer is laying out a new distribution room for a commercial building. The transformer capacity is 2,000 kVA. The available space is limited, and the room is adjacent to the main lobby. The engineer must choose between an oil-immersed transformer and a Dry Type Transformer. The oil-immersed unit requires a fire-rated vault, an oil containment pit, and a pressure relief vent. It also requires a 3-hour fire separation from the lobby. The dry type unit requires none of these. It can be installed in the same room as the switchgear, with only a 1-hour fire separation if the insulation class is high enough. The difference in construction cost and usable floor space is significant. This guide explains how dry type transformer design meets indoor fire safety codes.
The fire safety classification of a transformer depends on the flammability of its dielectric and insulation systems. An oil-immersed transformer contains hundreds of liters of combustible mineral oil. If a fault occurs, the oil can ignite, and the fire can spread to adjacent equipment and the building structure. A Dry Type Transformer uses solid insulation materials that are self-extinguishing. The insulation does not contain free liquid. If a fault occurs, the insulation may char and produce smoke, but it does not pool and burn like oil. The table below compares the fire risk characteristics of the two types.
| Parameter | Oil-immersed transformer | Dry Type Transformer |
| Dielectric medium | Mineral oil (combustible) | Solid insulation (self-extinguishing) |
| Flash point | 140 – 160°C | N/A |
| Fire propagation risk | High (pool fire) | Low (charring only) |
| Smoke toxicity | High (oil smoke) | Low to moderate (depends on insulation) |
| Required fire separation | 3 hours (per NFPA 70) | 1 hour or none (per insulation class) |
The fire separation requirement is the most significant cost driver. A 3-hour fire-rated vault for an oil-immersed transformer can cost $30,000 to $50,000. A dry type transformer in a 1-hour rated room may cost $10,000 to $15,000. In some cases, if the transformer is installed in a non-combustible area with adequate ventilation, no fire separation is required. In our factory, we manufacture Dry Type Transformer units with insulation systems that meet the most stringent fire safety requirements. Lugao Power Co.,Ltd has been producing these transformers for over 15 years.
The insulation class determines the maximum operating temperature and the fire safety performance of the Dry Type Transformer. The most common insulation classes are Class F (155°C), Class H (180°C), and Class C (220°C). Class H and Class C insulation systems are typically used for indoor transformers because they can withstand higher temperatures and have better fire resistance. The table below shows the insulation classes and their properties.
| Insulation class | Maximum temperature | Typical materials | Fire safety rating | Application |
| Class F | 155°C | Polyester, epoxy | Moderate | General purpose |
| Class H | 180°C | Silicone, aramid | Good | Indoor distribution |
| Class C | 220°C | Polyimide, ceramic | Excellent | High-risk areas |
In our factory, we use Class H insulation as the standard for our indoor Dry Type Transformer units. The insulation is a vacuum-pressure impregnated (VPI) epoxy system that is self-extinguishing and low smoke. The transformer is tested according to IEC 60076-11 for fire behavior. The test confirms that the transformer does not propagate fire and that the smoke emission is within the limit for indoor installation. Lugao provides the fire test report with every transformer.
Even though a Dry Type Transformer does not burn like oil, it still generates heat. The heat must be removed to prevent the insulation from exceeding its temperature limit. The ventilation requirement is determined by the transformer losses. For a 2,000 kVA transformer with 20 kW of losses, the required airflow is approximately 1.5 m³/s. The table below shows the ventilation requirements for different transformer sizes.
| Transformer capacity (kVA) | Total losses (kW) | Required airflow (m³/s) | Minimum clearance (mm) |
| 500 | 6 | 0.5 | 300 |
| 1,000 | 11 | 0.9 | 400 |
| 1,500 | 16 | 1.2 | 500 |
| 2,000 | 21 | 1.6 | 600 |
| 2,500 | 26 | 2.0 | 700 |
Design tip: The ventilation openings must be sized for the required airflow and the maximum allowable air velocity. The air velocity should not exceed 5 m/s to avoid noise and pressure drop. The inlet should be at the bottom of the room and the outlet at the top. The outlet should be provided with a fire damper that closes automatically in case of fire. In our factory, we provide a ventilation calculation for each Dry Type Transformer installation. Lugao Power Co.,Ltd also offers a temperature monitoring system that alerts the operator if the winding temperature exceeds the alarm limit.
The enclosure rating determines the environmental protection and the fire safety performance of the Dry Type Transformer. The most common enclosure ratings are IP00 (open), IP20 (finger-proof), IP23 (rain-proof), and IP54 (dust-proof and splash-proof). For indoor installation, IP20 is the minimum. IP23 is used for outdoor or high-humidity areas. The enclosure material also affects fire safety. A steel enclosure provides a fire barrier, while a plastic enclosure may not. The table below shows the enclosure ratings and their application.
| Enclosure rating | Protection level | Fire barrier | Typical installation |
| IP00 | None | None | Outdoor fenced area |
| IP20 | Finger-proof | None | Indoor electrical room |
| IP23 | Rain-proof | Moderate | Indoor with high humidity |
| IP54 | Dust and splash-proof | Good | Harsh indoor environment |
In our factory, we manufacture Dry Type Transformer units with steel enclosures rated IP20, IP23, or IP54. The enclosure is powder-coated for corrosion resistance. We also offer a sound-attenuated enclosure that reduces the noise level by 10 to 15 dB. The enclosure is designed to meet the fire safety requirements of NFPA 70 and IEC 60076-11. Lugao Power Co.,Ltd provides the enclosure certification and the fire test report for every transformer.
Dry Type Transformer design meets indoor fire safety codes by using self-extinguishing insulation materials, providing adequate ventilation, and offering enclosure options that contain fire and smoke. The insulation class (Class H or Class C) determines the fire separation requirement. The ventilation calculation ensures that the transformer does not overheat. The enclosure rating determines the environmental protection and the fire barrier. By selecting the right insulation class and enclosure, engineers can install a Dry Type Transformer in locations that would be prohibited for an oil-immersed transformer. Lugao Power Co.,Ltd has been manufacturing Dry Type Transformer units for over 15 years and provides full code compliance documentation for our customers.
Lugao Power Co.,Ltd manufactures Dry Type Transformer units with Class H and Class C insulation, VPI epoxy impregnation, and steel enclosures rated IP20, IP23, or IP54. We provide fire test reports, ventilation calculations, and code compliance guides for all of our products.